Unable to log via SSM with version 3.8.5.515

Report bugs/problems with ecuEdit

Re: Unable to log via SSM with version 3.8.5.515

Postby jmllh513 » Tue Aug 06, 2013 7:26 pm

just tried version 515 again and no luck at all, no data on min, current and max value boxes and soon thereafter a dialog box comes up saying connection to ecu has been interrupted. 502 works though has random disconnections with the same dialog box and sometimes rendering my usb port un-usable until after a hard reboot.
My setup is Windows 7 Pro 64 bit and using openport 2.0 with firmware from ecuflash 3252 beta.
jmllh513
 
Posts: 2
Joined: Tue Aug 06, 2013 7:07 pm

Re: Unable to log via SSM with version 3.8.5.515

Postby khalonen » Fri Sep 20, 2013 8:11 pm

Did E85 conversion today, did base tune with scaling injectors and tip-in enrichment. Seems to work fine for daily driving and AF learnings within +/- 2%
Although run into some problems in WoT tuning and logging it with Ecuedit:

My logger randomly freezes and disconnects from ECU during WoT pulls? This haven't happened before, can't remember what version of ecuedit I used last time logging but I think there has been update after that.
Empiric testing showed that If my driver (I'am myself passanger with laptop telling when to WoT pull) releases wot pull immediately when the logger freezes it will recover without error?
If I just drive around normally and don't do hard pulls everything works perfectly. Could these be caused by loose connection at OBDII port or something with Openport 2.0?

Here's some logs from disconnects:
Code: Select all
[18:53:04.974] Connect using protocol SSM started...
[18:53:04.975] Using port OpenPort 2.0 J2534 ISO/CAN/VPW/PWM
[18:53:04.978] Try to connect #1
[18:53:04.978] Write Init string
[18:53:04.991] Waiting for ECU response
[18:53:05.494] Found ECU 2E44594005
[18:53:05.494] Connection established
[18:54:09.390] // error: null message from ECU
[18:54:09.626] // error: LQ: response timeout
[18:54:10.631] // error: invalid message haeader
[18:54:10.876] // error: LQ: response timeout
[18:54:11.881] // error: invalid message haeader
[18:54:12.204] ECU disconnecting...
[18:54:12.726] ECU disconnected.

[18:54:35.247] Connect using protocol SSM started...
[18:54:35.248] Using port OpenPort 2.0 J2534 ISO/CAN/VPW/PWM
[18:54:35.250] Try to connect #1
[18:54:35.251] Write Init string
[18:54:35.266] Waiting for ECU response
[18:54:35.768] Found ECU 2E44594005
[18:54:35.769] Connection established
[18:54:53.256] // error: LQ: response timeout
[18:54:54.506] // error: LQ: response timeout
[18:54:55.756] // error: LQ: response timeout
[18:54:57.006] // error: LQ: response timeout
[18:54:58.256] // error: LQ: response timeout
[18:54:58.313] ECU disconnecting...
[18:54:59.618] ECU disconnected.


Would the custom port setting abowe help me? Finished with the car for tonight but might try them later.
And anyway I'am out of injector at 5500rpm 1.3 bar so not in a hurry with this now.
Now back to injector shopping->
khalonen
 
Posts: 1
Joined: Mon Jan 23, 2012 5:07 pm

Previous

Return to Troubleshooting

Who is online

Users browsing this forum: No registered users and 1 guest

cron